Heat transfer fluids

Bolztherm AW-65

BOLZTHERM® AW-65 is suitable for use in the liquid phase in closed, non-pressurized heat transfer systems with forced circulation in a temperature range of -12 °C to 350 °C, ensuring that the maximum film temperature of 380 °C is not exceeded. The optimal operating range is between 70 °C and 330 °C. For applications outside this optimal range, please contact us for consultation.

Typical characteristics Unit Standard Value
Area of application [°C] - -12 to 350
Max. flow temperature [°C] - 350
Max. film temperature [°C] - 380
Viscosity at 40 °C [mm²/s] DIN 51562-1 17.0
Viscosity at 100 °C [mm²/s] DIN 51562-1 2.85
Density at 20 °C [kg/m³] DIN 51757 1044
Pourpoint [°C] DIN ISO 3016 <-35
Flash point [°C] DIN EN ISO 2719 200
Flash point [°C] DIN EN ISO 2592 210
Acid value [mg KOH/g] DIN ISO 6618 ≤ 0.2
Coke residue [w.-%] DIN EN ISO 10370 < 0.1
Boiling point at 1013 mbar [°C] - 390